title: "Gas Storage Wellhead Heating Project"
url: "https://xgthermal.com/projects/gas-storage-wellhead-heating/"
language: "en"
---

# Gas Storage Wellhead Heating Project

Indirect phase-change heating for high-pressure multiphase flow before choke-valve pressure reduction.

Project overview

## Application and supply scope.

The project configuration below summarizes the supplied equipment and its process application.

Year

2023

Region

Hebei, China

Application

Underground gas storage withdrawal

Supply scope

Two vertical explosion-proof heater packages

![CCTV-13 news coverage showing XGTHERMAL-supplied heating equipment at a gas storage facility](https://xgthermal.com/images/projects/jidong-oilfield-cctv-news.webp)

CCTV-13 news coverage showing equipment supplied by XGTHERMAL.

The engineering challenge

## Conditions shaping the heating duty.

Gas withdrawal requires pressure reduction, which can sharply lower stream temperature and increase hydrate formation and blockage risks.

The mixed stream also presents wax-deposition concerns. High-pressure containment, hazardous-area operation, coastal corrosion and remote control must be addressed together.

Equipment configuration

## What the package includes.

Equipment capacities, interfaces and controls are matched to the project application.

Package count

2

Process medium

Natural gas, crude oil and produced water

Position in process

Upstream of wellhead choke-valve pressure reduction

Heat-transfer route

Indirect negative-pressure phase-change cycle

Power control

SCR regulation with PID temperature control

Environment

Outdoor winter service and coastal salt-spray exposure

Our approach

## Engineering the complete heating package.

### Process-stream isolation

Electric elements heat an intermediate fluid. Vapor condenses on the process coil and returns by gravity, keeping the heating elements separate from the high-pressure oil, gas and water stream.

### High-pressure mechanical design

The process stream flows through a pressure-rated helical coil. Pressure-retaining parts, flange interfaces, corrosion allowance and inspection strategy are selected around the application.

### Control and field protection

PLC control, a local HMI and SCR/PID regulation are combined with remote operation, temperature and pressure protection, no-flow shutdown and ESD. External coating addresses the coastal environment.

Project value

## Delivery and application value.

### Heating before throttling

The heating objective is to provide thermal margin before choke-valve pressure reduction, helping manage hydrate, wax and low-temperature blockage risks.

### Integrated field equipment

The vertical package combines high-pressure process design, indirect heat transfer and automation. No exact operating pressure or measured risk-reduction percentage is published in this case summary.

Related equipment

## Vacuum Phase-Change Indirect Heater

Explore the equipment family and engineering considerations relevant to this application.

[View Product Details](https://xgthermal.com/products/vacuum-assisted-phase-change-indirect-heater/)