Year

2026

Region

Xinjiang, China

Application

Molecular sieve regeneration gas heating

Rated heater power

1,200 kW

Supply scope

Integrated indirect electric heating skid

Project status

Site installation and commissioning in progress at the time of reporting

![Installed heating skid with electrical cabinets and an elevated access platform](https://xgthermal.com/_astro/overview.BTxVvPXf.webp)

The heating package during site installation, viewed from the electrical cabinet side.

The engineering challenge

## Conditions shaping the heating duty.

The dehydration unit required hot regeneration gas to remove moisture from the molecular sieve beds. The package had to deliver the required heat to pressurized natural gas and accommodate cold outdoor conditions.

At this scale, the heating duty also shaped the electrical distribution, thermal oil circulation and protection strategy. The package brought these systems together on a common skid for connection to the plant.

Equipment configuration

## What the package includes.

Equipment capacities, interfaces and controls are matched to the project application.

Heating arrangement

Electric resistance heater, closed thermal oil circuit and separate gas heat exchanger

Gas outlet target

230–240 °C

Gas-side exchanger design pressure

5.0 MPa

Oil circulation

Two pumps, one duty and one standby

Control

PLC with staged heater control and outlet temperature feedback

Heater Ex marking

Ex db IIB T4 Gb

Package scope & interfaces

## Beyond the heater body.

The integration and handover scope documented for this project.

### Thermal equipment

Electric thermal oil heater, gas heat exchanger and elevated expansion vessel.

### Circulation and piping

Duty and standby circulation pumps, insulated piping and skid-mounted valves.

### Power and controls

Heater power cabinets, PLC controls and interlocks integrated with the package.

Site photography

## Circulation equipment and heater nameplate

![Two thermal oil circulation pumps next to insulated pipework and the gas heat exchanger](https://xgthermal.com/_astro/circulation.BDaKvn6e.webp)

The heating skid during installation, viewed from the circulation pump side.

![Original BDRG-1200 heater nameplate showing the electrical ratings and explosion protection marking](https://xgthermal.com/_astro/nameplate.BMr5pTRO.webp)

The original BDRG-1200 electric heater nameplate.

Technical specifications

## BDRG-1200 equipment and design data

The heater nameplate and gas-side exchanger describe separate components. Efficiency and temperature control figures are project specifications.

| Parameter | Specification |
| --- | --- |
| Heater model | BDRG-1200 |
| Equipment tag | PE-10402 |
| Rated power | 1,200 kW |
| Rated voltage and frequency | 380 VAC / 50 Hz |
| Rated current | 1,800 A |
| Explosion protection | Ex db IIB T4 Gb (certificate SYEx23.11204X) |
| Ingress protection | IP65 |
| Process medium | Molecular sieve regeneration gas (natural gas) |
| Reported gas processing capacity | 180,000 m³/day |
| Gas inlet temperature | 50 °C |
| Gas outlet temperature | 230–240 °C |
| Process gas operating pressure | 2.8–4.0 MPa(g) |
| Gas-side exchanger design pressure | 5.0 MPa |
| Heater nameplate limits | Maximum allowable working pressure 1.0 MPa; design temperature ≤135 °C |
| Process connections | DN100, weld-neck (WN) raised-face (RF) flanges |
| Heating method | Electric resistance heating with an indirect thermal oil circulation loop |
| Efficiency figures in the project specification | Thermal efficiency ≥95%; heating efficiency ≥98% |
| Load adjustment in the project specification | 20–120%, with stepless SCR control |
| Specified temperature control accuracy | ±2 °C, with primary and auxiliary heating stages |
| Circulation pumps | Two air-cooled horizontal centrifugal thermal oil pumps, one duty and one standby |
| Expansion vessel | Nitrogen blanketing and a magnetostrictive level transmitter |
| Control system | PLC, 10-inch touchscreen and Modbus RTU/TCP communication with station controls |
| Project ambient temperature range | −35.9 to 42.9 °C |
| Heater serial number and manufacture date | 2604003G / April 2026 |
| Manufacturing standards listed in the project specification | GB/T 150, GB/T 151, NB/T 10936, JB/T 2379, SY/T 0524 |

Our approach

## Engineering the complete heating package.

### Separate the two circuits

The electric elements heat the circulating thermal oil. A separate exchanger transfers heat to the regeneration gas, keeping the process gas out of the electric heater vessel.

### Control outlet temperature

Gas outlet temperature feedback adjusts heater output. Overtemperature, low oil level and loss of circulation are monitored through the package protection system.

### Prepare for outdoor operation

The skid incorporates cabinet heating, instrument insulation and heat tracing where needed for cold-weather service.

Project value

## Delivery and application value.

### One package for multiple disciplines

The electrical, thermal oil and process gas systems were assembled as a package before shipment, reducing the amount of interconnecting work left for site installation.

### Electric heat for a high-temperature gas duty

The 1,200 kW package uses an electrically heated thermal oil loop to serve the regeneration gas duty without a fired heater in the package.