• ISO-Certified Manufacturer

    ISO 9001 · 14001 · 45001
  • Electric Heating Expertise

    Manufacturing Since 1992

Hazardous-Area
Wellhead Heater

Compact electric heating for localized heat retention around oilfield wellhead equipment.

Equipment Overview

Compact heat.
Right where it is needed.

The Explosion-Proof Wellhead Heater is a compact electric heater for localized heating and heat retention around oilfield wellhead equipment. Its fully sealed, die-cast aluminum enclosure is designed for exposed oilfield environments involving oil, water and wind-blown sand.

Manufactured by XGTHERMAL in China, the heater uses a thermal-balance operating principle that does not rely on a separate electronic temperature-control component. The external silicone-rubber cable is heat-resistant, oil-resistant and aging-resistant. Supplied mounting components support straightforward installation and removal.

Discuss Your Requirements
Compact wellhead heater with sealed housing and supply cable
Assembly shown. Ratings and mounting follow the selected model.

Localized heat retention

Compact heating assembly for wellhead equipment.

Sealed aluminum housing

Die-cast construction with silicone-rubber supply cable.

Thermal-balance operation

Heat generation and dissipation reach an installation-dependent equilibrium.

Applications & Installation

Localized heating
around wellhead equipment.

This compact heater provides local heat retention. It is not an in-line process heater for bulk crude oil or gas heating, a heat-tracing cable system, or a complete wellhead winterization package.

Wellhead heat retention

Supplies local heat where the wellhead installation needs protection from ambient cooling.

Sealed construction

The fully sealed die-cast aluminum enclosure is a defining feature of this local heater.

External supply cable

Silicone-rubber cable provides heat, oil and aging resistance for the external electrical connection.

Outdoor oilfield service

Sealed construction is intended for sites exposed to oil, water and sand within the unit’s rated limits.

Installation and removal

Supplied mounting components support straightforward installation and removal at the wellhead.

Construction & Operation

Built for installation
and service at the wellhead.

The fully sealed die-cast aluminum enclosure houses the heating assembly. Its structural design contributes to explosion protection and ingress protection; the applicable ratings must be checked for the selected model. External silicone-rubber cabling and supplied mounting components support straightforward installation and removal.

  • Die-cast aluminum enclosure with a sealed construction
  • Silicone-rubber external cable with heat, oil and aging resistance
  • Supplied mounting components for straightforward wellhead installation and removal
  • Installation according to the selected model’s instructions

As the heater temperature rises, heat dissipation increases until a dynamic thermal equilibrium is established under the applicable installation and operating conditions. Temperature then stabilizes at that balance. This is not a claim of a universal fixed temperature or immunity to overheating.

01

Independent of electronic temperature control

The heater’s thermal-balance operation does not rely on a separate electronic temperature-control component.

02

Installation-dependent equilibrium

The equilibrium temperature depends on the installation and operating conditions; it is not an adjustable electronic temperature setpoint.

03

Electrical installation protection

Install and connect the heater in accordance with the selected model’s instructions and normal site electrical requirements.

04

Model-specific documentation

Request the applicable datasheet, installation instructions and certification documents for the selected model before confirming hazardous-area suitability.

Technical Data & Delivery Scope

Review the details that matter.

Published values are reference information. Request the applicable model datasheet, installation instructions and certification documents before procurement.

Request a Datasheet

Specifications

Specification ParametersSpecification Details
Rated VoltageAC 380 V, 50 Hz (customizable)
Rated PowerUp to 500 W
Protection ClassIP65
Explosion-Proof GradeEx db IIB; temperature class by selected model

Standards & Certification

Standards and Certification AreaReference / RouteHow XGTHERMAL Supports It
Explosion-proof design basisGB/T 3836 / IEC 60079Standards referenced in the earlier product specification. Confirm applicability and supporting documents for the selected model.
Product specificationQ/SXGDL01-2022, BDR seriesReference retained from the earlier product specification; request the applicable model datasheet and documents.
Destination-market documentationSelected-model evidence requiredProvide the required documents with your inquiry. Availability must be confirmed for the exact model; certification is not implied by this page.
Ingress protectionIEC 60529 / IP65Confirm enclosure rating and installation conditions, including cable entry integrity. IP65 is not a submersion rating.
Inspection and handoverModel-specific records and instructionsAgree the applicable inspection records, Ex documents and installation instructions before supply.

Certification availability depends on the final equipment configuration, destination market, hazardous-area classification and third-party assessment. Listed standards describe engineering and documentation support, not blanket certification for every configuration.

Supply Scope

NameOrigin/BrandRemarks
Sealed Aluminum HousingShenyang Xinguang Electric Manufacturing Co., Ltd.Die-cast enclosure for the wellhead heating assembly
Heating AssemblyShenyang Xinguang Electric Manufacturing Co., Ltd.Rating confirmed in the applicable model datasheet
Supply CableSupplied with the assemblySilicone-rubber cable; length and termination requirements confirmed with the order
Mounting ComponentsSupplied for the selected installationInstallation and removal arrangement matched to the equipment layout
Selection Support

From operating conditions
to a practical equipment review.

Provide the installation, available power supply, site conditions and quantity to help identify the appropriate model and supporting documents.

What to share with our team.

Share photographs or drawings of the intended installation and relevant dimensions. Selection is based on localized heat retention and the model’s installation conditions; a flowing-liquid heat-duty calculator does not apply.

  • Required quantity
  • Application / installation description
  • Photograph or drawing of the installation
  • Available power supply
  • Ambient and site conditions
  • Hazardous-area requirements
  • Relevant installation dimensions
  • Required documentation
Send Your Specification

Common engineering questions.

What is the Explosion-Proof Wellhead Heater used for?

It is a compact electric heater for localized heating and heat retention around oilfield wellhead equipment. It is not a complete wellhead winterization package or an electric heat-tracing cable system.

Is this heater used to heat flowing crude oil or natural gas?

No. This product provides localized wellhead heat retention, not bulk temperature rise of a flowing production stream. In-line and circulation process heaters serve a different duty.

How does the thermal-balance principle work?

As the heater temperature rises, heat dissipation increases until a dynamic thermal equilibrium is established under the applicable installation and operating conditions. Temperature stabilizes at that balance; the equilibrium is not a universal fixed temperature.

Does thermal-balance operation require an electronic temperature controller?

The heater’s thermal-balance operation does not rely on a separate electronic temperature-control component. This does not mean the heater can never overheat or that electronic controls are inherently unsafe. Follow the selected model’s operating and installation instructions.

What information should be provided with an inquiry?

Please provide quantity, an application description, installation photographs or drawings, relevant dimensions, available power supply, ambient/site conditions, hazardous-area requirements and required documentation.

What technical documents are available for the selected model?

Contact XGTHERMAL for the applicable datasheet, installation instructions and certification documents. Availability and coverage must be confirmed for the exact model; this page does not establish destination-market certification.

Manufacturing & Supply

Confirm the model.
Review the installation.

Manufacturing since 1992, with engineering and supply support for industrial electric heating equipment.

Review Our Capabilities

Product selection for your wellhead installation.

Share an installation photograph or drawing, relevant dimensions and site requirements so we can identify the applicable product configuration and documentation.

  • Wellhead equipment and intended local heat-retention use.
  • Mounting dimensions, installation photograph or drawing.
  • Hazardous-area requirements and procurement documents.
  • Available electrical supply and ambient/site conditions.
Review Your Installation

Have a specification?
Let’s review it together.

Share your process conditions, drawings and delivery requirements.

Chat on WhatsApp