Oil storage tank coils
Hot water transfers heat through coils to help maintain stored-oil temperature.
An integrated electric heat source for oilfield tank coils, radiator circuits and circulating-water heating.
This skid-mounted electric circulation heating system combines an electric heater, circulating pump, make-up water tank and control cabinet on a common base. Heated water leaves the skid, delivers heat through tank coils or radiators, and returns for reheating.
In tank-coil service, water circulates through the equipment while oil remains inside the tank. We configure heating power, pump flow, piping and controls around your external circuit, installation space and available electrical supply.
Discuss Your Requirements
Supply and return water serves an external heating circuit.
Heating and circulation equipment assembled on one base.
Temperature, pump operation, flow and water level reviewed together.
The connected tank coils, radiators and heating branches determine the required heat duty, supply temperature, circulation flow and pump head.
Hot water transfers heat through coils to help maintain stored-oil temperature.
A packaged heat source for single-well tanks with compatible water circuits.
An electric alternative where fuel availability is limited and site power is suitable.
Heated water for compatible facility radiators or existing heating-circuit retrofits.
A heater alone does not establish a working heat-supply system. The pump must circulate sufficient water, the external coils or radiators must transfer the required heat, and the controls must coordinate temperature, flow and water level.
After releasing heat, return water is reheated on the skid. The make-up tank supports replenishment; expansion, venting and pressure protection are selected for the final circuit arrangement. Equipment selection also considers water quality, scaling, insulation and winter freeze protection.
Supply-water temperature feedback regulates heat input against the circuit setpoint.
Circulation is established before heating; stop and cooldown sequences follow the agreed design.
Insufficient circulation or water level inhibits heating and initiates an alarm or shutdown.
High-limit temperature, pump overload and electrical-fault trips complement normal control.
Published options provide a starting point. Final values and certification requirements are confirmed for your project.
| Specification Parameters | Specification Details |
|---|---|
| Rated Voltage | AC 380 V, 50 Hz (customizable) |
| Rated Power | Up to 500 kW |
| Inlet/Outlet Specification | Custom supply / return connections |
| Control Mode | PLC / microcontroller / digital controller (optional) |
| Alarm Mode | Over-temperature, over-pressure, low flow, low water level and electrical faults |
| Design Pressure | Project-specific system rating |
| Control Cabinet | Explosion-proof / non-explosion-proof |
| Protection Class | IP65 |
| Explosion-Proof Grade | Exdb IIB T1~T6Gb Exdb IIC T1~T6Gb |
| Standards and Certification Area | Reference / Route | How XGTHERMAL Supports It |
|---|---|---|
| Explosion-proof design basis | IEC 60079 / GB/T 3836 | Design reference for applicable heater, motor, terminal enclosure and hazardous-area electrical components. |
| EU / international Ex certification | ATEX / IECEx | Project-specific certification route can be supported when required by the destination market and final hazardous-area classification. |
| Eurasian market access | EAC / TR CU 012/2011 | Certification and technical documentation support can be coordinated for Russia, Kazakhstan and other EAEU destinations. |
| Oil & gas procurement documents | IOGP JIP33 S-723 Electrical Process Heaters | JIP33-aligned data sheets, inspection and test plans, vendor document register and technical query response can be prepared for EPC review. |
| Pressure boundary | ASME BPVC Section VIII / PED 2014/68/EU | Applicable pressure components and documentation are reviewed against circuit conditions and the destination requirements. |
| Electrical cabinet and machine safety | IEC 61439 / IEC 60204-1 | Control cabinet layout, component selection, wiring practice and electrical protection can be configured around project requirements. |
| Functional safety | IEC 61511 / SIL | SIL-rated safety loop design can be coordinated when independent shutdown or safety instrumented functions are specified. |
| Circulating-fluid compatibility | Project fluid specification | Heater, pump, tank, seal and valve materials are reviewed for the circulating fluid and water quality. |
| Inspection and handover package | EN 10204 3.1, NDT reports and FAT records | Material certificates, pressure test records, non-destructive testing reports, electrical test records and factory acceptance test files can be supplied. |
| Ingress protection | IEC 60529 | IP65 / IP66 enclosure protection can be selected for outdoor oilfield stations and harsh operating environments. |
Certification availability depends on the final equipment configuration, destination market, hazardous-area classification and third-party assessment. Listed standards describe engineering and documentation support, not blanket certification for every configuration.
| Name | Origin/Brand | Remarks |
|---|---|---|
| Heater Body | Shenyang Xinguang Electric Manufacturing Co., Ltd. | Heater pressure boundary and circulation connections |
| Heating Element | Shenyang Xinguang Electric Manufacturing Co., Ltd. | Material and surface heat load selected for the circulating fluid |
| Control Cabinet | Shenyang Xinguang Electric Manufacturing Co., Ltd. | Explosion-proof or safe-area cabinet available |
| Electrical Components | Delixi, Chint or project-approved equivalents | Temperature control, pump starter and electrical protection components |
| Instruments | Chuanyi, Anhui Tiankang, Beijing Tiantai or project-approved equivalents | Supply / return temperature, circulation flow, water level and pressure monitoring |
| Circulating Pump | Project-selected supplier | Flow, head and seal arrangement matched to the circuit |
| Make-up Water Tank | Included in the package | Capacity, connections and level monitoring selected by project |
| Skid Base and Piping | Shenyang Xinguang Electric Manufacturing Co., Ltd. | Common base with supply / return and maintenance interfaces |
| Valves | Zhejiang Gong'ao, Zhejiang Huisheng or approved equivalents | Isolation, drain and other circuit valves as specified |
Start with the heating demand of the connected tanks or radiators. Final selection reviews warm-up time, supply / return temperatures, circulation flow, distribution losses, coil capacity and pump head.
Send your circuit schematic, coil or radiator data and equipment specification. The heat carried by circulating water is only part of the review; it does not establish tank warm-up duty, coil capacity or the pump head required by your circuit.
A circulation heater is the heating component. This electric heating skid adds the circulating pump, make-up water tank, piping and controls needed to serve an external heating circuit. Buyers may also describe it as a packaged hot-water heating skid or an electric circulation heating unit.
In the tank-coil arrangement described here, water circulates through the skid and the storage tank coils; the oil remains in the tank. Direct crude oil heating and oil-water-gas process heating are different duties and require a separate equipment selection.
Pump flow is matched to the required heat transport and the permitted supply-to-return temperature difference. Pump head is determined from the heater, external piping, valves and coil resistance. Static head and suction conditions also need review according to the circuit arrangement.
It can be evaluated as an electric alternative where a suitable water circuit and sufficient electrical capacity are available. Selection must check the existing coil duty, site power supply and operating schedule. Energy cost depends on local electricity and fuel prices, so savings are assessed for each project.
Yes. XGTHERMAL is a China-based manufacturer of skid-mounted electric heating systems for oilfield applications. We support package configuration, coordinated controls, fabrication and project documentation for domestic and overseas customers.
Project documentation can be prepared around IEC 60079 / GB/T 3836 hazardous-area requirements, NDT, material certificates, FAT records and, where required, project-specific ATEX, IECEx, EAC or JIP33 alignment discussions.
Manufacturing since 1992, with 120+ projects delivered across our industrial heating equipment range.
Review Our CapabilitiesGeneral arrangement, supply and return connections, skid footprint, pump selection and electrical interfaces are coordinated with your team. Inspection and acceptance requirements are agreed for the complete package.
Share your process conditions, drawings and delivery requirements.