• ISO-Certified Manufacturer

    ISO 9001 · 14001 · 45001
  • Electric Heating Expertise

    Manufacturing Since 1992

High-Power DC
Electric Duct Heater

Project-engineered process-air heating powered by solar PV and suitable industrial DC systems.

Equipment Overview

DC electrical power.
Industrial process heat.

XGTHERMAL's High-Power DC Electric Duct Heater is engineered for industrial process-air heating from solar PV and other suitable DC power systems, with project-specific electrical, thermal and control integration.

A completed 500 kW / DC1000V photovoltaic-powered project demonstrates the application of high-power DC resistance heating in an industrial refinery environment.

Discuss Your Requirements
Concept illustration of a high-power DC electric duct heater
Concept illustration. Final construction follows the approved project design.

DC1000V reference

500 kW photovoltaic-powered project configuration.

Modular heating groups

Five 100 kW groups in the completed reference project.

Plant control integration

PLC-based local / remote operation and communication.

Applications

DC-powered process-air heating
for industrial applications.

The heater is configured around the available DC electrical architecture and air-heating duty. Daqing Refining is the completed reference; other applications remain subject to engineering review.

Solar PV Process-Air Heating

Uses photovoltaic electricity as the energy source for industrial process-air heating.

Industrial DC-Bus Heating

Duct-air heating integrated with a suitable industrial DC power architecture.

Refinery & Petrochemical Air Heating

Process or utility air heating where a suitable DC supply is available.

Industrial Electrification Projects

Electric process-air heating for facilities increasing the use of electrical energy.

Engineering & Operation

From solar electricity
to heated process air.

Photovoltaic-electric heating (PV-EH) converts solar-generated electricity into useful industrial heat. In a direct-DC architecture, the duct heater is the thermal load within the project’s electrical system—a form of industrial Power-to-Heat, also described as PV-to-Heat.

Selection combines the air-heating duty with DC voltage and current, switching and protection, heating-group arrangement, temperature control and plant integration.

  • Solar PV → project DC power system → approved DC interface → duct heater → heated process air.
  • Heating elements and airflow design matched to thermal duty and pressure-drop limits.
  • Heating groups, connection equipment and controls engineered together.
  • XGTHERMAL’s heater-side scope is defined separately from PV generation and DC power management unless expressly included.
Explore Solar PV & Direct-DC Heating
01

PLC-Based Control

The reference project uses a Siemens SIMATIC S7-200 SMART PLC for heater-system control.

02

Modular Heating Groups

The 500 kW reference configuration is divided into five 100 kW heating groups.

03

Overtemperature Protection

Heating-group temperature monitoring and overtemperature protection are provided.

04

Local / Remote Operation

The reference system supports both local and remote operating modes.

05

Plant Integration

DCS signals and Modbus RTU / RS485 communication are supported in the reference project.

Technical Data & Delivery Scope

Review the details that matter.

The 500 kW / DC1000V values describe the completed reference configuration, not a fixed rating for every heater. Final ratings, protection and certification follow the approved project design.

Request a Datasheet

Specifications

Specification ParametersSpecification Details
Rated Heating Power500 kW
Power SupplyDC1000V
Heating Groups5 × 100 kW
Heated MediumAir
InstallationDuct / inline air heating
Control SystemPLC-based
Reference PLCSiemens SIMATIC S7-200 SMART
OperationLocal / remote
Plant InterfaceDCS
CommunicationModbus RTU / RS485
Temperature ProtectionHeating-group overtemperature protection
Power ApplicationPhotovoltaic-powered industrial heating

Standards & Certification

AreaEngineering Position
Hazardous-area engineeringReference-project procurement identifies the 500 kW unit as an Ex electric heater. Final construction and marking must be confirmed for each project.
Explosion-proof design basisGB/T 3836 / IEC 60079 may be reviewed according to the required project configuration.
Destination-market certificationATEX / IECEx / EAC certification routes can be evaluated where required by the destination market and final equipment configuration.
EU electrical conformityEuropean-market requirements must be assessed against the final electrical design and supply scope.

Certification availability depends on the final equipment configuration, destination market, hazardous-area classification and third-party assessment. Listed standards describe engineering and documentation support, not blanket certification for every configuration.

Supply Scope

Typical Heater-Side ScopeScope Boundary
DC electric duct heater assemblyConfigured to the approved thermal and mechanical duty
Heating elements / heating groupsGrouping and ratings confirmed during project engineering
Electrical junction / connection equipmentHeater-side interface matched to the agreed battery limit
Temperature instrumentationMonitoring and protection points defined during engineering
PLC-based heater controlLocal / remote control and approved operating logic
Plant interfaceDCS and communication interface as specified
Project documentationFinal document list agreed with the purchaser
Selection Support

From operating conditions
to a practical equipment review.

Share the process-air duty and DC supply envelope so we can review the thermal load, electrical interfaces and control requirements.

What to share with our team.

Air heating requires airflow, air properties, temperature rise and operating pressure, together with the DC supply and protection architecture. The flowing-liquid calculator does not apply to this equipment.

  • Airflow and operating range
  • Air composition if not ordinary clean air
  • Inlet and target outlet temperature
  • Normal / minimum / maximum airflow
  • Design pressure and allowable pressure drop
  • DC supply voltage and available DC power
  • Minimum / normal / maximum DC operating conditions
  • Upstream DC power-system architecture
  • Ambient conditions and hazardous-area classification
  • Required destination-market certification
  • PLC / DCS and local / remote requirements
  • Communication, alarm and shutdown requirements
Send Your Specification

Common engineering questions.

What is a high-power DC electric duct heater?

It is a project-engineered resistance heater that uses a DC electrical supply to heat industrial air flowing through a duct or inline heating section.

Can the heater operate with photovoltaic power?

Yes, when the heater interface and upstream power architecture are engineered together. XGTHERMAL’s completed reference used photovoltaic electricity with a DC1000V heater interface.

What is photovoltaic-electric heating (PV-EH)?

Photovoltaic-electric heating (PV-EH) uses electricity generated by photovoltaic systems as an energy source for useful heat. In industrial applications, the electrical and thermal architecture depends on the project's PV/DC power system and process-heating requirements.

Does XGTHERMAL supply the photovoltaic power system?

Not automatically. The heater-side scope is defined separately from photovoltaic panels, power conversion, storage and plant-wide energy management unless those items are expressly included.

How is heater power divided and controlled?

Heating groups are arranged to the approved electrical architecture and control philosophy. The 500 kW reference project uses five 100 kW groups with PLC-based control.

Can the heater be engineered for hazardous areas?

The reference procurement identifies the unit as an Ex electric heater. Final hazardous-area design, marking and certification route must be confirmed for each project.

What information is required for heater sizing?

Provide the air duty, operating temperatures, flow range, pressure limits, DC supply envelope, upstream system architecture, installation conditions, area classification and plant-control requirements.

Manufacturing & Project Experience

500 kW of heating.
A completed DC reference.

XGTHERMAL engineered a photovoltaic-powered electric heating system for industrial air heating, with a DC1000V interface and five 100 kW heating groups.

Review Our Capabilities

PV-Powered Industrial Air Heating Project

The reference configuration combines duct-air heating with PLC-based local / remote operation and plant-control integration.

  • 500 kW heating capacity · DC1000V electrical interface.
  • Five independently arranged 100 kW heating groups.
  • Siemens SIMATIC S7-200 SMART PLC.
  • DCS signals · Modbus RTU / RS485 communication.
View Project Details

Have a specification?
Let’s review it together.

Share your air-heating duty, DC supply data and delivery requirements.

Chat on WhatsApp